Because the human femoral (ball) head is naturally large, it makes sense to implant a large, anatomic replacement
|
Company:
Date:
June 26, 2008
|
|
|
|
|
|
|
|
|
|
The C2a-Taper™ Acetabular System is a ceramic-on-ceramic hip articulating system. The bearing surfaces consist of ceramic femoral heads and acetabular liners. Both components are made of aluminum oxide manufactured by CeramTec AG.
|
Company:
Date:
June 26, 2008
|
|
|
|
|
|
|
|
|
|
Ceramic is the hardest implant material used in the body, and has the lowest wear rate of all, to almost immeasurable amounts (1000 times less than Metal-on-polyethylene).
|
Company:
Date:
June 26, 2008
|
|
|
|
|
|
|
|
|
|
Ceramic heads are harder than metal and are the most scratch resistant implant material. The hard, scratch resistant, ultra-smooth surface can greatly reduce the wear rate on the polyethylene bearing. The wear rate for this type of implant is less than Metal-on-Polyethylene
|
Company:
Date:
June 26, 2008
|
|
|
|
|
|
|
|
|
|
The Trident® Ceramic Acetabular System is a ceramic-on-ceramic implant system used to replace the "ball and socket" joint of a hip when a total hip replacement is performed for patients suffering from arthritis or related conditions. Unlike conventional hip implants, the Trident® system utilizes alumina ceramic-on-ceramic surfaces rather than metal-on-plastic or metal-on-metal. Ceramic-on-ceramic components have demonstrated significantly lower wear versus the conventional metal-on-plastic or metal-on-metal systems in the laboratory; therefore, it is anticipated that these improved wear charac
|
Company:
Date:
June 26, 2008
|
|
|
|
|
|
|
|
|
|
Echo™ Hip System Design Features
Reduced neck geometry enhances potential range of motion
Modified insertion hole allows for rotational control
Modified inserter aides in controlling version upon impaction
Polished proximal neck region
|
Company:
Date:
June 26, 2008
|
|
|
|
|
|
|
|
|
|
The shells are constructed of cobalt chrome and are available in 1mm increments to allow for exact sizing of the acetabulum. The bearing surface inside the shell is cross-linked polyethylene. The use of cross-linked polyethylene results in a significant reduction in the amount of particles that are created from wear compared to UHMWPE. There is an UHMWPE support ring inside the shell that is permanently fixed. There is also an UHMWPE locking ring that assembles above the support ring and locks into place once the head is inserted into the shell.
|
Company:
Date:
June 26, 2008
|
|
|
|
|
|
|
|
|
|
A new approach to stemmed total hip arthroplasty for patients in whom the condition of the femoral head or neck does not allow resurfacing, Corin has developed Optimom, a metal-on-metal stemmed large diameter total hip replacement.
|
Company:
Date:
June 26, 2008
|
|
|
|
|
|
|
|
|
|
The LINEAGE® Acetabular System with UHMWPE liners provide lipped options for increased femoral head coverage promoting a stable joint. Standard and lateralized options allow the center of rotation to be re-established, further aiding in optimum joint mechanics.
|
Company:
Date:
June 26, 2008
|
|
|
|
|
|
|
|
|
|
The LINEAGE® Acetabular System with ceramic liners builds on this clinical history using sophisticated manufacturing methods and materials to minimize wear debris generation.
|
Company:
Date:
June 26, 2008
|
|
|
|
|
|