The AccuDrain™ External CSF Drainage
System is used to drain cerebrospinal
fluid (CSF) from the ventricles of the
brain or the lumbar subarachnoid space
to a drainage bag. System components
facilitate CSF drainage, CSF sampling
and Intracranial Pressure (ICP)
monitoring.
|
Company:
Date:
November 03, 2008
|
|
|
|
|
|
|
|
|
|
The BACTISEAL® EVD Catheter system is a technically innovative anti-microbial impregnated catheter for external CSF drainage which reduces gram positive bacteria on catheter tube surfaces. Treated with the patented BACTISEAL® Advanced Impregnation Process, it reduces the potential for bacterial colonization on inner lumen and exterior catheter wall.
|
Company:
Date:
November 03, 2008
|
|
|
|
|
|
|
|
|
|
Medtronic Neurosurgery external drainage and monitoring (EDM) products meet a variety of needs for CSF drainage and monitoring. From the completely closed drainage and monitoring system of the Becker® EDMS to the ventriculostomy kit -- all products are designed for speed and convenience in emergency situations. All EDM products come with latex-free injection sites, minimizing the chance for adverse patient/personnel reactions to latex.
|
Company:
Date:
November 03, 2008
|
|
|
|
|
|
|
|
|
|
EDM ventricular catheters with and without BioGlide® are fabricated of radiopaque (barium impregnated) silicone tubing, and are packaged with stainless steel stylets inserted in the lumen. All EDM ventricular catheters include luerlock connectors to facilitate catheter connection to an external drainage system. The 35 cm EDM ventricular catheters include a trocar for catheter tunneling and a fixation collar for anchoring the catheter outside the catheter exit site.
|
Company:
Date:
November 03, 2008
|
|
|
|
|
|
|
|
|
|
EDM ventricular catheters with and without BioGlide® are fabricated of radiopaque (barium impregnated) silicone tubing, and are packaged with stainless steel stylets inserted in the lumen. All EDM ventricular catheters include luerlock connectors to facilitate catheter connection to an external drainage system. The 35 cm EDM ventricular catheters include a trocar for catheter tunneling and a fixation collar for anchoring the catheter outside the catheter exit site.
|
Company:
Date:
November 03, 2008
|
|
|
|
|
|
|
|
|
|
The CODMAN® EDS 3™ CSF External Drainage System was developed with input from more than 200 nurses and physicians. The clinicians who work every day with CSF drains inspired solutions that distinguish the CODMAN EDS 3: ease-of-use in an integrated pole clamp, filter protection from our new SPLASHFREE ™ valve, accurate hydrostatic leveling from a unique laser leveling device. The EDS 3 provides all this, plus upgraded stopcocks, pressure-resistant tubing, and a multi-functional drip chamber – all in a fully MRI-safe design.
|
Company:
Date:
November 03, 2008
|
|
|
|
|
|
|
|
|
|
Medtronic Neurosurgery external drainage and monitoring (EDM) products meet a variety of needs for CSF drainage and monitoring. From the completely closed drainage and monitoring system of the Becker® EDMS to the ventriculostomy kit -- all products are designed for speed and convenience in emergency situations. All EDM products come with latex-free injection sites, minimizing the chance for adverse patient/personnel reactions to latex.
|
Company:
Date:
November 03, 2008
|
|
|
|
|
|
|
|
|
|
The External CSF Drainage System, with blue-striped,
non-pressure tubing, is designed to be used with
or without a pole mount assembly. The system
includes: needleless sampling site, 50 ml graduated
burette, proximal transducer port, anti-microbial
hydrophobic vent, bonded in-line anti-reflux valve,
paper scale and removable 700 ml drainage bag.
|
Company:
Date:
November 03, 2008
|
|
|
|
|
|
|
|
|
|
The CODMAN® Lumbar External Drainage Catheter with Touhy needle is indicated for temporary access to the Lumbar Subarachnoid region as a means of draining cerebral spinal fluid (CSF) in order to reduce increased intracranial volume and pressure.
|
Company:
Date:
November 03, 2008
|
|
|
|
|
|
|
|
|
|
The MoniTorr ICP™ External CSF Drainage System is a closed
system. This system is used with a pole mount bracket assembly
for simple, accurate patient alignment. The patient line is
completely sealed. This system has a VentGuard™ feature which
inhibits contamination of the microbial barrier filter. Collection
bag has an anti-reflux valve.
|
Company:
Date:
November 03, 2008
|
|
|
|
|
|