1ml BD Luer-Lok™ Syringe with Detachable Needle
|
Company:
Date:
April 26, 2009
|
|
|
|
|
|
|
|
|
|
BD Viscoflow™ Cannula .60 x 22.0mm (23G x 7 / 8 in) angled 45°, 9mm from end. (100/sp)
|
Company:
Date:
April 26, 2009
|
|
|
|
|
|
|
|
|
|
BD Viscoflow™ Cannula .40 x 22.0mm (27G x 7 / 8 in) angled 45°, 9mm from end. (10/sp) For maintaining or forming anterior chamber and irrigating cornea during surgery. May be used for injection and removal of air, fluids, viscoelastic substances, and miotics.
Longer design from bend to tip allows for easier placement of viscoelastic to all meridians. May be used to coat intraocular lens prior to insertion. The dome shape and extra smooth tip provides safe insertion through wound and manipulation within the eye.
|
Company:
Date:
April 26, 2009
|
|
|
|
|
|
|
|
|
|
BD Visitec™ anterior chamber Cannula (Rycroft) .40 x 22.0 mm (27 G x 7/8 in.) (10/sp)
For maintaining or forming anterior chamber and irrigating cornea during surgery. May be used for injection and removal of air, fluids, viscoelastic substances, and miotics.
Dome shaped, extra smooth tip provides safe insertion through wound and manipulation within the eye.
|
Company:
Date:
April 26, 2009
|
|
|
|
|
|
|
|
|
|
Irrigating Cannulas
|
Company:
Date:
April 26, 2009
|
|
|
|
|
|
|
|
|
|
BD Visitec™ Bimanual irrigation Cannula, .80 x 17.0mm (21G x 5 / 8 in) thinwall Cannula. Curved 45°, .51mm open-end irrigation port (10/sp)
For removing cortical debris or viscoelastic substances while maintaining the chamber during ECCE. Irrigation and anterior chamber maintenance is provided by the irrigation cannula when attached to a gravity fluid source. Aspiration is provided through aspiration cannula when attached to suction. J shape and curved designs facilitate removal of cortical debris between 10 o'clock and 2 o'clock meridian.
Separate irrigation and aspirations cannulas insert
|
Company:
Date:
April 26, 2009
|
|
|
|
|
|
|
|
|
|
BD Visitec™ Bishop Harmon Cannula 1.1 x 25.0mm (19G x 1 in) angled 40°, 8mm from end. . (100/sp)
|
Company:
Date:
April 26, 2009
|
|
|
|
|
|
|
|
|
|
BD Visitec™ I and A Cannula (Simcoe) .60mm / .60mm (23G / 23G) thinwall Cannula Tubing: ID-1mm (.04 in); OD-2mm (.08 in) .30mm aspiration port (3/sp) For removing cortical debris or viscoelastic substances while maintaining the chamber during extracapsular and intercapsular/endocapsular cataract procedures. Standard Simcoe I and A cannulas provide irrigation through luer hub and have an open end port. Aspiration is provided through the 25 cm (10 in.) flexible tubing.
|
Company:
Date:
April 26, 2009
|
|
|
|
|
|
|
|
|
|
BD Visitec™ irrigation handle, 9.3cm (3 5 / 8 in) long. Standard male luer fitting (20/sp)
Designed for attaching to instruments for irrigation or aspiration during eye surgery.
|
Company:
Date:
April 26, 2009
|
|
|
|
|
|
|
|
|
|
BD Visitec™ olive tip polisher .60 x 25.0 mm (23 G x 1 in.); .33 mm end port angled 30°, 10 mm from end; micro-etched 2 mm from end olive shape tip is 2 mm long x 1 mm wide (10/sp)
For removing cortical debris from the posterior, anterior and equatorial regions of capsular bag. Micro etched tips are slightly roughened for gentle polishing. Flexible tip cannulas have a sleeve for atraumatic insertion and removal. Provides a squeegee effect for polishing.
|
Company:
Date:
April 26, 2009
|
|
|
|
|
|